Isolation Amplifier for Precise Motor Current Sensing
Toshiba DCA121x02 isolation amplifiers deliver 85 dB SNR, 100 kV/µs CMTI and 500 ns overcurrent feedback for servo drives and industrial robots.
www.global.toshiba

Servo amplifiers and industrial robots need motor current data that is both precise enough for smooth control and fast enough to protect power devices when a fault occurs, while the measurement must cross the boundary between high-voltage drive circuits and low-voltage control electronics. Toshiba Electronic Devices & Storage Corporation has started shipping the DCA121x02 series, two analog-output isolation amplifiers designed for current sensing in motor drive systems.
Why Isolated Current Sensing Matters in Motor Drives
Motor current is a key variable for control and for monitoring equipment condition. In noisy drive environments it must be detected accurately and transmitted safely from the high-voltage side to the controller. Current-sensing devices therefore need high noise immunity, high signal accuracy and reliable insulation, and they should report overcurrent events to the control side within a very short time.
85 dB SNR and High Common-Mode Transient Immunity
Using Toshiba's signal processing technology based on high-precision AD conversion, the DCA121x02 series achieves a typical signal-to-noise ratio of 85 dB, defined with a 0.5 Vp-p, 1 kHz sine input. The amplifiers accept a linear input range of ±250 mV, as typically produced across a shunt resistor, and output a differential analog signal with a gain of 8.16 to 8.24 V/V. Common-mode transient immunity (CMTI) of at least 100 kV/µs supports signal transmission where steep common-mode voltage changes occur, as in fast-switching inverter stages.
Fast Overcurrent Feedback in the DCA121102
The series comprises the standard DCA121002 and the DCA121102, which adds Toshiba's overcurrent fast-feedback function. While the normal propagation delay is 1.6 µs (typ.), the DCA121102 reports an overcurrent condition to the control side within 500 ns (typ.), excluding external processing. Combining precise current measurement and fast fault response in one device shortens the time before protection circuits are activated.
Package, Insulation and Operating Range
Both devices use an SOIC8-W package with a minimum creepage distance of 8 mm and an isolation voltage of 5000 Vrms (min). The widely used package supports design flexibility and second-source procurement strategies for business continuity. Supply voltage ranges from 3.0 to 5.5 V and the operating temperature range is -40 to 125 °C.
More information is available on the Toshiba isolators and solid state relays page.
Additional Context
This section details technical specifications and competitive benchmarking not included in the original product announcement.
Shunt-based isolated current sensing is a common alternative to Hall-effect current sensors in servo drives, because a low-ohmic shunt combined with an isolation amplifier offers good linearity and low offset drift. The functional requirements for digital isolators and isolation components are described in IEC 60747-17, while isolation voltage ratings such as 5000 Vrms are typically verified according to UL 1577. Comparable reinforced isolation amplifiers with ±250 mV shunt input ranges are offered by other semiconductor manufacturers, for example the AMC1300 family from Texas Instruments. Toshiba has not published comparative SNR or CMTI data against competing devices in this announcement.
Edited by Evgeny Churilov, Induportals Media - Adapted by AI.
toshiba.semicon-storage.com